Product introduction
Product Overview
| Item | Description |
| Product Name | Frequency Inverter/ AC Drive |
| Model Number | E5-PA-4TxxX / E5-A-4TxxX |
| Power Range | 1.5kW-560kW |
| Rated Input Voltage | 3 phase 380V/480V |
| Rated Output Voltage | 3 phase 0 to rated input voltage |
| Input Frequency | 50Hz/60Hz |
| Applicable Motor | Asynchronous Motor |
| Control Mode | Constant Pressure Control, V/F Control, Vector V/F Control |
| Communication | Modbus 485 RTU |
| IP Class | Standard IP20 |
| Overload Capacity | 120% 1 minute, 160% 0.5 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) |
Feature
■ Many features are the same as E5-P, and strong starting torque and complete protection functions
■ Water Supply VFD Sleep Control about small pump: let system in sleep state to control , and control the special small pump in sleep state
■ Alternate to work on time: avoid the rust of the pump and prevent same pump to non-stop work
■ Automatic switch: when the water supply changes in large flow, the pump can be automatically switched to control
■ Over-voltage and under-voltage control: real-time monitoring of the system, alarm of over-pressure and under-pressure, optional stop processing
■ Multi-period pressure control: under change of daily water demand, smooth water supply with multiple designated pressure in stages, and save electricity and water everyday
■ Designated day and pressure to supply water under constant pressure: specific pressure can be set when the pressure changes significantly over the weekend or on a fixed day, and it will be finished with weekly Cycle
■ Smooth switch: users can adjust according to the site ;to ;avoid current shock and hydraulic shock
Model Explanation

Product Catalogue
E5−PA−4T□□□X ; 3 Phase 400V Variable/Light Load Application
| Power(kW) | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | |
| Motor(kW) | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | |
| Output | Voltage(V) | 3 phase 0~Rated Voltage | ||||||||||||||
| Rated Current(A) | 3.3 | 5 | 7.5 | 11 | 17 | 22 | 30 | 38 | 45 | 57 | 75 | 91 | 112 | 142 | 176 | |
| Overload capacity | 120% 1 minute, 160% 0.5 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||||||
| Input | Voltage/ frequency | 3 phase 380V~480V;50Hz/60Hz | ||||||||||||||
| Allowable voltage range | 323V~528V;Voltage imbalance:≤3% ;allowable frequency fluctuation:±5% | |||||||||||||||
| Rated Current(A) | 3.6 | 5.5 | 8.3 | 12 | 19 | 25 | 33 | 40 | 50 | 62 | 80 | 100 | 121 | 156 | 194 | |
| Braking unit | Built-in as standard | External braking unit needed | ||||||||||||||
| IP Class | IP 20 | |||||||||||||||
| Cooling mode | Natural air cooling | Forced air cooling | ||||||||||||||
| Power(kW) | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | 560 | ||
| Motor(kW) | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | 560 | ||
| Output | Voltage(V) | 3 phase 0~Rated Voltage | ||||||||||||||
| Rated Current(A) | 210 | 253 | 304 | 350 | 380 | 426 | 470 | 520 | 600 | 650 | 690 | 775 | 860 | 950 | ||
| Overload capacity | 120% 1 minute, 160% 0.5 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||||||
| Input | Voltage/ frequency | 3 phase 380V~480V;50Hz/60Hz | ||||||||||||||
| Allowable voltage range | 323V~528V;Voltage imbalance:≤3% ;allowable frequency fluctuation:±5% | |||||||||||||||
| Rated Current(A) | 196* | 232* | 282* | 326* | 352* | 385* | 437* | 491* | 580* | 624* | 670* | 755* | 840* | 920* | ||
| Braking unit | External braking unit needed | |||||||||||||||
| IP | IP 20 | |||||||||||||||
| Cooling mode | Forced air cooling | |||||||||||||||
E5-PA-4T110X and above power class is standard external DC reactor

Installation Dimension
![]() | ![]() |
E5−PA−4T11X and below power class
![]() | ![]() |
E5−PA−4T15X and above power class
Voltage | Model | Appearance, Installation Dimensions(mm) | Weight (kg) | |||||||
W | H | D | W1 | H1 | D1 | T1 | Hole d | |||
400V | E5−PA−4T1.5X | 118 | 190 | 155 | 105 | 173 | 40.8 | 3 | 5.5 | 1.5 |
E5−PA−4T2.2X | 118 | 190 | 175 | 105 | 173 | 60.5 | 4 | 5.5 | 2.6 | |
E5−PA−4T3.7X | ||||||||||
E5−PA−4T5.5X | ||||||||||
E5−PA−4T7.5X | 155 | 249 | 185 | 136 | 232 | 69 | 8 | 5.5 | 3 | |
E5−PA−4T11X | ||||||||||
E5−PA−4T15X | 210 | 337 | 200 | 150 | 324 | 107.5 | 2.5 | 7 | 8.5 | |
E5−PA−4T18.5X | ||||||||||
E5−PA−4T22X | 285 | 440 | 220 | 200 | 425 | 107.5 | 2.5 | 7 | 17 | |
E5−PA−4T30X | ||||||||||
E5−PA−4T37X | ||||||||||
E5−PA−4T45X | 315 | 575 | 227 | 220 | 553 | 123.5 | 2.5 | 10 | 25 | |
E5−PA−4T55X | ||||||||||
E5−PA−4T75X | 400 | 615 | 265 | 270 | 590 | 123.5 | 3.0 | 10 | 35 | |
E5−PA−4T90X | ||||||||||
E5−PA−4T110X | 465 | 745 | 325 | 343 | 715 | 156 | 3.0 | 12 | 55 | |
E5−PA−4T132X | ||||||||||
E5−PA−4T160X | 540 | 890 | 385 | 370 | 855 | 205.5 | 4.0 | 14 | 85 | |
E5−PA−4T185X | ||||||||||
E5−PA−4T200X | ||||||||||
E5−PA−4T220X | ||||||||||
E5−PA−4T250X | 700 | 1010 | 385 | 520 | 977 | 210 | 4.0 | 14 | 125 | |
E5−PA−4T280X | ||||||||||
E5−PA−4T315X | ||||||||||
E5−PA−4T355X | 810 | 1358 | 425 | 520 | 1300 | 210 | 4.0 | 14 | 215 | |
E5−PA−4T400X | ||||||||||
E5−PA−4T450X | ||||||||||
E5−PA−4T500X | ||||||||||
E5−PA−4T560X | ||||||||||
Applications
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
V&T Water Pump Controller Representative Industry
The use of variable frequency drive (VFD): a VFD is used to regulate the speed and torque of the Motor according to the variation of the load in order to improve the Motor energy efficiency. The Constant Pressure Water Supply Inverter of Shenzhen V&T Technologies Co.,Ltd. are widely used in Constant pressure water supply,Water pump, Fan etc.

Download
undefined
Water Supply Inverter
Product Model:
Categories:
Keywords:
Download File:
overseas@v-t.net.cn
Online Message
Ready to grow your business? Your next great business opportunity starts with an inquiry.