Product introduction

Product Overview

ItemDescription
Product NameFrequency Inverter/ AC Drive
Model NumberV9-H-4TxxG/xxL
Power Range0.75kW-630kW
Rated Input Voltage3 phase 380V/480V
Rated Output Voltage3 phase 0 to rated input voltage
Input Frequency50Hz/60Hz
Applicable MotorAsynchronous Motor, Synchronous Motor
Control ModeV/F Control, Vector Control, Sensorless Vector Control, Sensor Vector Control, Vector Torque Control
CommunicationModbus 485 RTU, CANOpen, Profibus-DP, Profinet
IP ClassStandard IP20
Overload Capacity150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)

 

Feature

■Fast and accurate motor parameter self-learning, suitable for a variety of motors: synchronous/asynchronous/reluctance/high-speed/torque motor, V/F vector encoder closed loop integrated.

■Asynchronous and non-inductive V/F control, 200% torque output at 0.25Hz in electric state, 200% torque output at 1Hz in power generation state.

■Good voltage and current control, high speed, high frequency, deep field weakening, wave-by-wave current limiting, multiple protections.

■Modular compact structure design, high power density.

■Support multiple encoders and multiple high-speed communication protocols.

■Integrated drive and control, expandable PLC and motion control card.

■Multiple language keyboard, friendly interface, reliable and easy to use.

 

Model Explanation

Product Catalogue

V9−H−4T□□□GThree-phase 400V constant torque / heavy duty application

Power(kW)0.751.52.23.75.57.5111518.522303745557590110
Motor power (kW)0.751.52.23.75.57.5111518.522303745557590110
OutputVoltage (V)3-phase 0 -rated input voltage
Rated current (A)2.53.85.59131724303945607591112150176210
Overloa capability150% 1min,180% 10s, 200% 0.5s,10min interval (Inverse-time characteristic)
InputRated voltage / frequency3-phase 380V-480V;50Hz/60Hz
Allowabl voltage323V-528V; degree of voltage unbalance:≤3%;allowable frequency fluctuations:±5%
Rated current (A)2.84.26.1101519263343506683100123165194231
Brake unitStandard built-inBuilt-in brake unit is optional
Protection levelIP20
Cooling methodSelf−coolingForced cooling
Power(kW)132160185200220250280315355400450500560630
Motor power (kW)132160185200220250280315355400450500560630
OutputVoltage (V)3-phase 0 -rated input voltage
Rated current (A)2533043503804264705206006506907758609501100
Overload 
capability
150% 1min,180% 10s, 200% 0.5s,10min interval (Inverse-time characteristic)
InputRated voltage / frequency3-phase 380V-480V;50Hz/60Hz
Allowable voltage323V-528V;degree of voltage unbalance:≤3%;allowable frequency fluctuations:±5%
Rated current (A)2322823263523854374915806246707558409201050
Brake unitExternal braking unit needed
Protection levelIP20
Cooling methodForced cooling

Note: 

0.75kW~15kW:No built-in DC reactor ;

18.5kW~110kW:Optional DC reactor ;

132kW~160kW:Standard built-in DC reactor ;

185kW~500kW:Standard external DC reactor;

560kW~630kW:Standard built-in AC input reactor;

Higher power level product can be customized

220V, 690V, 1140Vand other voltage level inverters can becustomized.

 

V9−H−4T□□□LThree−phase 400V Variable torque/light−duty Application

Power(kW)1.52.23.75.57.5111518.522303745557590110132
Motor power (kW)1.52.23.75.57.5111518.522303745557590110132
OutputVoltage(V)3-phase 0 -rated input voltage
Rated current (A)3.357.5111722293545577091110144180216242
Overload capability120% 1min,160% 0.5s,10min interval (Inverse-time characteristic)
InputRated voltage /frequency3-phase 380V-480V;50Hz/60Hz
Allowable voltage
323V-528V; degree of voltage unbalance:≤3%; allowable frequency fluctuations:±5%
Rated current (A)3.65.58.31219253239506177100121158198238266
Brake unitStandard built-inBuilt-in brake unit is optional
Protection levelIP20
Cooling methodSelf−coolingForced cooling
Power(kW)160185200220250280315355400450500560630710
Motor power (kW)160185200220250280315355400450500560630710
OutputVoltage (V)3-phase 0 -rated input voltage
Rated current (A)
325365405440495547610695770866950110012001300
Overload capability120% 1min,160% 0.5s,10min interval (Inverse-time characteristic)
InputRated voltage /frequency3-phase 380V-480V;50Hz/60Hz
Allowable voltage
323V-528V; degree of voltage unbalance:≤3%; allowable frequency fluctuations:±5%
Rated current (A)282326352385437491580670755840920105011501250
Brake unitExternal braking unit needed
Protection levelIP20
Cooling methodForced cooling

Note:  

1.5kW - 18.5kW: No built-in DC reactor ;

 22kW~132kW: Optional DC reactor ;

 160kW~185kW: Standard built-in DC reactor ;

 200kW~560kW: Standard external DC reactor ;

 630kW~710kW: Standard built-in AC input reactor;

 Higher power level product can be customized ;

 220V, 690V, 1140V and other voltage level inverters can be customized.

 

Technical Specification

Control characteristicsControlmodeSensor-less controlSensor control
Applicable motor type

Synchronous motor

Asynchronous motor

Synchronous motor

Asynchronous motor

Starting torque

●Asynchronousmotor:

200% of rated torque at 0.25Hz

●Synchronousmotor:

150% of rated torque at 1.5% of rated speed

200% of rated torque at 0 speed
Speed regulation range1:2001:5000
Steady speed precision± 0.5%± 0.02%
Maximum speed

VF control: 600Hz

Vector control:600 Hz;

Note: Higher frequency products can be customized

600Hz

Note: Higherfrequencyproducts can be customized

Torque controlYY
Torquecontrolprecision±5%±3%
Torque response time<20ms<10ms
Positioning controlNY
Positioning;precisionN±1;pulse
Product functionKey functionTorque limit, speed control, positioning control, motorauto tune,deepflux-weakening;control, current limit control, over-voltage control, under-voltage control,motorspeed tracing function, droop control, oscillation suppression, random carrier frequency, inertia auto-tune, etc.
Speed reference sourceModbus communication, Keypad,external digital input, analog;AI1/AI2/AI3,high speed pulse input,simple PLC, PID,CAN, PROFIBUS DP, PROFINET,etc.
Dynamicbrake

Brakeunit action voltage: 650 ~ 750V.

The brake unit can be built-in for 110kW and below equipment

●0.75~15kW: brake;unit is built- in as standard.

●18.5~110kW:;brake unit is built- in as optional.

CommunicationBuilt-inModbus-RTU communication, the maximum distance up to 500 meters.
Keypad

LED Keypad and LCD Keypad are optional

the Keypad can be used asremote-control boxvia straight-through wired cable.;

Common DC busSupport common DC busdirectly
Independent air ductAll series product adopts independent duct design
Protection functionPower supply under-voltage, over-current protection, over-voltage protection,auto-tune fault, module protection, heat-sink over-temperature protection, drive overload protection, motor overload protection, peripheral protection, current abnormal detection, output short-circuit to ground protection, EEPROM abnormal detection, temperature sampling disconnection, encoder disconnection, analog input abnormal detection, motor over-temperature, communication fault, hardware overload protection, etc.
Efficiency

At rating condition:

●0.75kW to 7.5kW:≥ 93%

●11kW to 45kW:≥ 95%

●55kW and higher power class:≥ 98%

EnvironmentOperating site

●Install vertically in a well-ventilated electrical cabinet. Horizontal or other installation methods are not allowed.

●The cooling medium is air.

● Installed in an environment free from direct sunlight, dust, corrosive gases, flammable gases, no oil mist, no steam, no dripping.

Ambient temperature

●−10~+40℃

●Derating use when the temperature between 40 to 50℃, the rated output current is reduced by 1% for every 1 °C increasing.

Humidity5~95%,no condensation is allowed.
Altitude

●0~2000;meters

●Derating use when the altitude over 1000 meters, the rated output current is reduced by 1% for every 100-meter rising.

Vibration

●3.5 m/s2,2~9Hz

●10 m/s2,9~200Hz

●15 m/s2,200~500Hz

Storage temperature−40~+70℃.

 

Motor Wiring

Short circuit or grounding of the Three Phase Inverter output terminals is prohibited. Otherwise, it will cause damage to the internal components of the drive.

Avoid output cables (U/V/W) short circuit or short circuit to enclosure, otherwise there is a risk of electric shock.

It is strictly forbidden to connect a capacitor or phase lead LC/RC noise filter to the output of the Universal Speed AC Drive, otherwise the drive will be damaged.

When a contactor is installed between the drive and the motor, the switching action of the output contactor cannot be performed during the operation of the drive, otherwise a large current will flow into the drive to and the drive will report fault information.

Cable length between drive and motor: When the cable between the Profibus-DP Inverter and the motor is too long, the high-order harmonic leakage current at the output will adversely affect the drive and peripheral devices. It is recommended to install a output AC reactor when the motor cable exceeds 100 meters, and contact the manufacturer to inquire whether the carrier frequency needs to be modified.

 

        

 

Installation dimension


 

 

V9−H−4T7.5G/11L and below power class

 


 

 

V9−H−4T11G/15L and above power class

 

Voltage

Model

Outline and mounting dimension (mm)

Weight

(kg)

W

H

D

W1

H1

T1

Mounting hole diameter

400V

V9−H−4T0.75G/1.5L11819015510517335.51.5
V9−H−4T1.5G/2.2L11819017510517345.52.6
V9−H−4T2.2G/3.7L
V9−H−4T3.7G/5.5L
V9−H−4T5.5G/7.5L15524918513623285.53
V9−H−4T7.5G/11L
V9−H−4T11G/15L1982991901602831.268
V9−H−4T15G/18.5L
V9−H−4T18.5G/22L2233482081953351.5610
V9−H−4T22G/30L
V9−H−4T30G/37L2644302352304181.5718
V9−H−4T37G/45L
V9−H−4T45G/55L3055452702455231.51035
V9−H−4T55G/75L
V9−H−4T75G/90L3385803102705601.51052
V9−H−4T90G/110L
V9−H−4T110G/132L
V9−H−4T132G/160L4009173233208903.01275
V9−H−4T160G/185L
V9−H−4T185G/200L5408903853708554.01485
V9−H−4T200G/220L
V9−H−4T220G/250L5408904163708554.01485
V9−H−4T250G/280L70010103855209774.014125
V9−H−4T280G/315L
V9−H−4T315G/355L7001010418.55209774.014125
V9−H−4T355G/400L810135842552013004.014215
V9−H−4T400G/450L810135842552013004.014215
V9−H−4T450G/500L
V9−H−4T500G/560L

 

Applications


 

 

 

 

 

 

 

 

 

Profinet Frequency Drive Representative Industry

Whenever a load has either a variable torque or a variable speed, a VFD should be considered to control torque and speed. V9 series universal speed AC drive of Shenzhen V&T Technologies Co.,Ltd. is suitable for Printing Packaging, Petrochemical, Textile, Cable Machinery, Food Packaging, Electric Vehicles, Plastic Machinery, Metal Products Equipment, Centrifuges and High-end applications requiring closed-loop vector or torque control.

 

Download

undefined

undefined

0.75kW-2.2kW V9 Series High Performance Universal Speed AC Drive

Product Model:

As the AC Drive manufacturer in china, V&T has rich experience in electric drive fields. V&T V9−H Series General Purpose Inverter is a high-performance vector control and torque controlled frequency drive. Vector control technology and torque control technology are employed. It can better meet the needs of various transmission applications.Voltage range covers 200V, 400V, 690V, and 1140V. The product power range covers 0.4kW to 3MW.

Keywords:

Download File:


E-mail

Online Message

Ready to grow your business? Your next great business opportunity starts with an inquiry.


Security verification
Send Inquiry Now