Product Overview

ItemDescription
Product NameFrequency Inverter/ AC Drive
Model NumberVY−IS−4Txx−I0(20180402)−xx
Power Range0.75kW-500kW
Rated Input Voltage3 phase 380V/480V
Rated Output Voltage3 phase 0 to rated input voltage
Input Frequency50Hz/60Hz
Control ModeV/F Control, Vector Control, Sensorless Vector Control, Vector Torque Control
IP ClassStandard IP20
Overload Capacity150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)

 

Feature

3 Phase Energy-Saving Inverter excellent current and voltage control technology, accelerating with 0.1S command, the driver runs stably without tripping.

■ Wide range torque output: the motor torque output is stable within the range of pressure and flow setting to ensure the quality of the processed work-piece.

■ Green output: It adopts advanced power module drive mode, which will not interfere with the control loop and sensor of the injection molding machine. 

■ With process curve memory function, users do not need to change energy-saving system parameters when changing molds.

 

Product Catalog

VY−IS−4T□□□X−I0(20180402)−□Three-phase 400V Constant torque/heavy-duty application

Power (kW)0.751.52.23.75.57.5111518.5223037455575
Motor power (kW)0.751.52.23.75.57.5111518.5223037455575
OutputVoltage (V)Three-phase 0 to rated input voltage
Rated current (A)2.53.85.59131724303945607591112150
Overload capacity150% ;1 minute, 180% ;10 seconds, 200% ;0.5 second, interval: 10 minutes (inverse time lag feature)
InputRated voltage/frequencyThree-phase 380V/480V; 50Hz/60Hz
Allowable voltage range323V ~ 528V; Voltage imbalance ≤3%; allowable frequency fluctuation: ±5%
Rated current (A)2.84.26.1101519263343506683100123165
Braking unitBuilt-in as standardBuilt-in as option
Protection classIP20
Cooling modeForced air convection cooling
Power (kW)90110132160185200220250280315355400450500 
Motor power (kW)90110132160185200220250280315355400450500 
OutputVoltage (V)Three-phase 0 to rated input voltage
Rated current (A)176210253304350380426470520600650690775860 
Overload capacity150% ;1 minute, 180% ;10 seconds, 200% ;0.5 second, interval: 10 minutes (inverse time lag feature)
InputRated voltage/frequencyThree-phase 380V/480V; 50Hz/60Hz
Allowable voltage range323V ~ 528V; Voltage imbalance ≤3%; allowable frequency fluctuation: ±5%
Rated current (A)160*196*232*282*326*352*385*437*491*580*624*670*755*840* 
Braking unitExternal braking unit
Protection classIP20
Cooling modeForced air convection cooling

* VY−IS−4T90−I0(20180402)-24 ;and above power class are equipped with external DC reactor as standard.

 

Technical Specifications

Control features

Control mode

Vector control ;1

Vector control ;2

Startup torque

0.50Hz ;180%

0.25Hz ;180%

Speed adjustment range

1:100

1:200

Speed stabilization precision

± 0.5%

± 0.2%

Torque control

N

Y

Torque precision

-

±5%

Torque response time

-

<20 ms

Product functions

Key functions

Under-voltage adjustment, switching of AC operation grounding, protective grounding and DC operation grounding, rotation speed tracing, torque limitation, multi-speed operation (up to 23 speeds), auto-tuning, S curve acceleration/deceleration, slip compensation, PID regulation, drooping control, current limiting control, manual/auto torque increase, current limiting.

Frequency setting mode

Frequency can be set via operation panel, UP/DN terminal, or analog inputs of AI1 / AI2/A3, or terminal pulse DI, and can also be set through communication with host computer ;

Frequency range

0.00 ~ 300.00 Hz ; Note: In the control mode of vector control 1 ; 0.0 ~ 3000.0 Hz, the range can be customized according to the customer demand

Startup frequency

0.00~60.00Hz

Acceleration/deceleration time

0.1~36000s

Powered braking capacity

Driver of 400V voltage grade: Braking unit action voltage: 650 ~ 750V ;

Operating time: 100.0s

The braking unit can be selected for VY−H−4T18.5G/22L~ VY−JY−4T75G/90L

DC braking capacity

DC braking initial frequency: 0.00 ~ 300.00Hz; DC braking current: Constant torque: 0.0 ~ 120.0%, Variable torque: 0. 0 ~ 90.0%

DC braking time: 0.0 ~ 30.0s; there is no initial waiting time for the DC braking to realize quick braking

Magnetic flux braking function

Ongoing action and no action upon deceleration as option, no action upon deceleration at default

Unique functions

Multi-functional M key

The unique multi-functional key is used to set the frequently used operations: JOG, emergent stop, Running command issuing mode switch , menu switching

Multiple menu modes

Basic menu mode, fast menu mode. Menu mode of Non-factory setting function codes, Menu mode of last changed 10 function codes

Parameter copy

The standard operation panel can realize the parameter upload, download and display the copy progress. User can select to forbid the overwriting of the uploaded parameters.

Displayed/hidden function code

The customer can select to display or hide the function codes by themselves.

Dual RS485 communication ports

Support Modbus protocol (RTU). The standard operation panel can realize the function of remote control box with a maximum distance of 500m.

Operation panel

Button type or shuttle type operation panel optional, protection class: IP20 as standard, IP54 as option

Shared DC bus

The full series can realize shared DC bus supply for several drivers.

Independent duct

The full series adopts independent duct design and supports the installation of heat-sink outside the cabinet

Universal expansion interface

Universal expansion board equipped with CPU for supporting customers secondary development: physical interface SPI bus, software protocol Modbus

Expansion card

User’s secondary development card, injection molding machine interface card, PG feedback card, air compressor control card, communication adapter card, power monitoring card, phase sequence detection card, external power rectifying card

Power-up auto-detection

Realizing the power-up auto-detection of internal and peripheral circuits, including motor grounding, abnormal +10V power supply output, abnormal analog input, and disconnection

Protection function

Power supply under-voltage, over-current protection, over-voltage protection, interference protection, abnormal comparison reference input, auto-tuning failure, module protection, heatsink over-temperature protection, driver overload protection, motor overload protection, peripheral protection, abnormal current detection, output to ground short circuit, abnormal power failure during operation, abnormal input power, output phase failure, abnormal EEPROM, relay suction pull-on anomaly, temperature sensor taking sample anomaly, encoder disconnection, abnormal +10V power supply output, abnormal analog input, motor over-temperature (PTC), abnormal communication, abnormal version compatibility, abnormal copying, abnormal expansion card connection, terminal mutual exclusion detection failure, hardware overload protection

Efficiency

At rated power, 7.5kW and below power class ≥93%, 45kW and below power class ≥95%, 55kW and above power class ≥98%

Environment

Operating site

The driver shall be mounted vertically in the electric control cabinet with good ventilation. Horizontal or other installation modes are not allowed. The cooling medium is the air. The driver shall be installed in the environment free from direct sunlight, dust, corrosive gas, combustible gas, oil mist, steam and drip.

Ambient temperature

-10 ~ +40ºC, derated at 40 ~ 50ºC, the rated output current shall be decreased by 1% for every temperature rise of 1ºC

Humidity

5 ~ 95%, no condensing

Altitude

0 ~ 2000 m, derated above 1000 m, the rated output current shall be decreased by 1% for every rise of 100m

Vibration

3.5mm, 2~9Hz; 10 m/s 2,9~200Hz; 15 m/s, 200~500Hz

Storage temperature

-40~+70ºC

 

Motor Wiring

It is forbidden to short circuit the Hydraulic Servo Drive Controller output terminals or short circuit to ground, otherwise the internal components of the variable frequency inverter will be damaged.

Do not short circuit the output cable to the universal variable frequency drive enclosure, otherwise electric shock may happen.

It is forbidden to connect the output terminal of the inverter to the capacitor or LC/RC noise filter with phase lead, otherwise, the internal components of the inverter may be damaged.

When contactor is installed between the inverter and motor, it is forbidden to switch on/off the contactor when the V&T AC Frequency Drive is running; otherwise, large current will flow into the industrial inverter, triggering the inverter protection action.

Length of cable between the 3 Phase Frequency Converter and motor. If the cable between the frequency inverter and the motor is too long, the high−order harmonic leakage current of the output end will cause adverse impact on the Single Phase To 3 Phase Inverter Converter and the peripheral devices. Output AC reactor should be installed if the motor cable is longer than 100m, Refer to the following table for the switching frequency setting.

 

Installation dimension


 

 
VY−IS−4T7.5−I0(20180402)−06−24 and blow power class

 

 

VY−IS−4T11−I0(20180402)−06−24 and above power class

VY−IS Product outline, mounting dimension, and weight

Voltage class

Driver model

Outline and mounting dimension (mm)

Approximate weight

(kg)

W

H

D

W1

H1

D1

T1

Hole d

400V

VY−IS−4T0.75−I0(20180402)−24

118

190

155

105

173

40.8

3

5.5

1.5

VY−IS−4T1.5−I0(20180402)−24

118

190

175

105

173

60.5

4

5.5

2.6

VY−IS−4T2.2−I0(20180402)−24

VY−IS−4T3.7−I0(20180402)−24

VY−IS−4T5.5−I0(20180402)−24

155

249

185

136

232

69

8

5.5

3

VY−IS−4T7.5−I0(20180402)−24

VY−IS−4T11−I0(20180402)−24

210

337

200

150

324

107.5

2.5

7

8.5

VY−IS−4T15−I0(20180402)−24

VY−IS−4T18.5A−I0(20180402)−06−24

285

440

220

200

425

107.5

2.5

7

17

VY−IS−4T22A−I0(20180402)−06−24

VY−IS−4T30A−I0(20180402)−06−24

VY−IS−4T37A−I0(20180402)−06−24

315

575

227

220

553

123.5

2.5

10

25

VY−IS−4T45A−I0(20180402)−06−24

VY−IS−4T55A−I0(20180402)−06−24

400

615

265

270

590

123.5

3.0

10

35

VY−IS−4T75A−I0(20180402)−06−24

VY−IS−4T90−I0(20180402)−24

465

745

325

343

715

156

3.0

12

55

VY−IS−4T110−I0(20180402)−24

VY−IS−4T132−I0(20180402)−24

540

890

385

370

855

205.5

4.0

14

85

VY−IS−4T160−I0(20180402)−24

VY−IS−4T185−I0(20180402)−24

VY−IS−4T200−I0(20180402)−24

VY−IS−4T220−I0(20180402)−24

700

1010

385

520

977

210

4.0

14

125

VY−IS−4T250−I0(20180402)−24

VY−IS−4T280−I0(20180402)−24

VY−IS−4T315−I0(20180402)−24

810

1358

425

520

1300

210

4.0

14

215

VY−IS−4T355−I0(20180402)−24

VY−IS−4T400−I0(20180402)−24

810

1358

425

520

1300

210

4.0

14

215

VY−IS−4T450−I0(20180402)−24

VY−IS−4T500−I0(20180402)−24

 

Applications


 

 

 

 

 

 

 

 

 

 

Representative Industry

As an advanced China Hydraulic Drive System Manufacturers,The use of V&T frequency drive (VFDs): a VFD is used to regulate the speed and torque of the Motor according to the variation of the load in order to improve the Motor energy efficiency. The technology of AC-VFD-AC drives power overcomes the small range and poor speed adjustment performance. Shenzhen V&T Technologies Co.,Ltd. AC servo drives is suitable for Air Compressor Speed Drive, Injection moulding machine drive system, Die Casting Machine AC Drive, Energy-saving industry etc

Download

undefined

undefined

VY-IS Series High Performance Servo Drive

Product Model:

For the energy saving of the injection molding machine, the servo is to realize the closed-loop feedback control, the system dynamic response is fast, and the control precision is high. Servo is the product of inverter development to the advanced stage, and inverter is the mother of servo. The innovation of asynchronous servo cleverly combines the advantages of frequency conversion energy-saving technology and synchronous servo energy-saving technology, while overcoming their respective shortcomings.

Keywords:

Download File:


E-mail

Online Message

Ready to grow your business? Your next great business opportunity starts with an inquiry.


Security verification
Send Inquiry Now