Product introduction
Product Overview
| Item | Description |
| Product Name | Frequency Inverter/ AC Drive |
| Model Number | VY−IS−4Txx−I0(20180402)−xx |
| Power Range | 0.75kW-500kW |
| Rated Input Voltage | 3 phase 380V/480V |
| Rated Output Voltage | 3 phase 0 to rated input voltage |
| Input Frequency | 50Hz/60Hz |
| Control Mode | V/F Control, Vector Control, Sensorless Vector Control, Vector Torque Control |
| IP Class | Standard IP20 |
| Overload Capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) |
Feature
■ 3 Phase Energy-Saving Inverter excellent current and voltage control technology, accelerating with 0.1S command, the driver runs stably without tripping.
■ Wide range torque output: the motor torque output is stable within the range of pressure and flow setting to ensure the quality of the processed work-piece.
■ Green output: It adopts advanced power module drive mode, which will not interfere with the control loop and sensor of the injection molding machine.
■ With process curve memory function, users do not need to change energy-saving system parameters when changing molds.
Product Catalog
VY−IS−4T□□□X−I0(20180402)−□Three-phase 400V Constant torque/heavy-duty application
| Power (kW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | |
| Motor power (kW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | |
| Output | Voltage (V) | Three-phase 0 to rated input voltage | ||||||||||||||
| Rated current (A) | 2.5 | 3.8 | 5.5 | 9 | 13 | 17 | 24 | 30 | 39 | 45 | 60 | 75 | 91 | 112 | 150 | |
| Overload capacity | 150% ;1 minute, 180% ;10 seconds, 200% ;0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||||||
| Input | Rated voltage/frequency | Three-phase 380V/480V; 50Hz/60Hz | ||||||||||||||
| Allowable voltage range | 323V ~ 528V; Voltage imbalance ≤3%; allowable frequency fluctuation: ±5% | |||||||||||||||
| Rated current (A) | 2.8 | 4.2 | 6.1 | 10 | 15 | 19 | 26 | 33 | 43 | 50 | 66 | 83 | 100 | 123 | 165 | |
| Braking unit | Built-in as standard | Built-in as option | ||||||||||||||
| Protection class | IP20 | |||||||||||||||
| Cooling mode | Forced air convection cooling | |||||||||||||||
| Power (kW) | 90 | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | ||
| Motor power (kW) | 90 | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | ||
| Output | Voltage (V) | Three-phase 0 to rated input voltage | ||||||||||||||
| Rated current (A) | 176 | 210 | 253 | 304 | 350 | 380 | 426 | 470 | 520 | 600 | 650 | 690 | 775 | 860 | ||
| Overload capacity | 150% ;1 minute, 180% ;10 seconds, 200% ;0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||||||
| Input | Rated voltage/frequency | Three-phase 380V/480V; 50Hz/60Hz | ||||||||||||||
| Allowable voltage range | 323V ~ 528V; Voltage imbalance ≤3%; allowable frequency fluctuation: ±5% | |||||||||||||||
| Rated current (A) | 160* | 196* | 232* | 282* | 326* | 352* | 385* | 437* | 491* | 580* | 624* | 670* | 755* | 840* | ||
| Braking unit | External braking unit | |||||||||||||||
| Protection class | IP20 | |||||||||||||||
| Cooling mode | Forced air convection cooling | |||||||||||||||
* VY−IS−4T90−I0(20180402)-24 ;and above power class are equipped with external DC reactor as standard.
Technical Specifications
Control features | Control mode | Vector control ;1 | Vector control ;2 |
Startup torque | 0.50Hz ;180% | 0.25Hz ;180% | |
Speed adjustment range | 1:100 | 1:200 | |
Speed stabilization precision | ± 0.5% | ± 0.2% | |
Torque control | N | Y | |
Torque precision | - | ±5% | |
Torque response time | - | <20 ms | |
Product functions | Key functions | Under-voltage adjustment, switching of AC operation grounding, protective grounding and DC operation grounding, rotation speed tracing, torque limitation, multi-speed operation (up to 23 speeds), auto-tuning, S curve acceleration/deceleration, slip compensation, PID regulation, drooping control, current limiting control, manual/auto torque increase, current limiting. | |
Frequency setting mode | Frequency can be set via operation panel, UP/DN terminal, or analog inputs of AI1 / AI2/A3, or terminal pulse DI, and can also be set through communication with host computer ; | ||
Frequency range | 0.00 ~ 300.00 Hz ; Note: In the control mode of vector control 1 ; 0.0 ~ 3000.0 Hz, the range can be customized according to the customer demand | ||
Startup frequency | 0.00~60.00Hz | ||
Acceleration/deceleration time | 0.1~36000s | ||
Powered braking capacity | Driver of 400V voltage grade: Braking unit action voltage: 650 ~ 750V ; Operating time: 100.0s The braking unit can be selected for VY−H−4T18.5G/22L~ VY−JY−4T75G/90L | ||
DC braking capacity | DC braking initial frequency: 0.00 ~ 300.00Hz; DC braking current: Constant torque: 0.0 ~ 120.0%, Variable torque: 0. 0 ~ 90.0% DC braking time: 0.0 ~ 30.0s; there is no initial waiting time for the DC braking to realize quick braking | ||
Magnetic flux braking function | Ongoing action and no action upon deceleration as option, no action upon deceleration at default | ||
Unique functions | Multi-functional M key | The unique multi-functional key is used to set the frequently used operations: JOG, emergent stop, Running command issuing mode switch , menu switching | |
Multiple menu modes | Basic menu mode, fast menu mode. Menu mode of Non-factory setting function codes, Menu mode of last changed 10 function codes | ||
Parameter copy | The standard operation panel can realize the parameter upload, download and display the copy progress. User can select to forbid the overwriting of the uploaded parameters. | ||
Displayed/hidden function code | The customer can select to display or hide the function codes by themselves. | ||
Dual RS485 communication ports | Support Modbus protocol (RTU). The standard operation panel can realize the function of remote control box with a maximum distance of 500m. | ||
Operation panel | Button type or shuttle type operation panel optional, protection class: IP20 as standard, IP54 as option | ||
Shared DC bus | The full series can realize shared DC bus supply for several drivers. | ||
Independent duct | The full series adopts independent duct design and supports the installation of heat-sink outside the cabinet | ||
Universal expansion interface | Universal expansion board equipped with CPU for supporting customers secondary development: physical interface SPI bus, software protocol Modbus | ||
Expansion card | User’s secondary development card, injection molding machine interface card, PG feedback card, air compressor control card, communication adapter card, power monitoring card, phase sequence detection card, external power rectifying card | ||
Power-up auto-detection | Realizing the power-up auto-detection of internal and peripheral circuits, including motor grounding, abnormal +10V power supply output, abnormal analog input, and disconnection | ||
Protection function | Power supply under-voltage, over-current protection, over-voltage protection, interference protection, abnormal comparison reference input, auto-tuning failure, module protection, heatsink over-temperature protection, driver overload protection, motor overload protection, peripheral protection, abnormal current detection, output to ground short circuit, abnormal power failure during operation, abnormal input power, output phase failure, abnormal EEPROM, relay suction pull-on anomaly, temperature sensor taking sample anomaly, encoder disconnection, abnormal +10V power supply output, abnormal analog input, motor over-temperature (PTC), abnormal communication, abnormal version compatibility, abnormal copying, abnormal expansion card connection, terminal mutual exclusion detection failure, hardware overload protection | ||
Efficiency | At rated power, 7.5kW and below power class ≥93%, 45kW and below power class ≥95%, 55kW and above power class ≥98% | ||
Environment | Operating site | The driver shall be mounted vertically in the electric control cabinet with good ventilation. Horizontal or other installation modes are not allowed. The cooling medium is the air. The driver shall be installed in the environment free from direct sunlight, dust, corrosive gas, combustible gas, oil mist, steam and drip. | |
Ambient temperature | -10 ~ +40ºC, derated at 40 ~ 50ºC, the rated output current shall be decreased by 1% for every temperature rise of 1ºC | ||
Humidity | 5 ~ 95%, no condensing | ||
Altitude | 0 ~ 2000 m, derated above 1000 m, the rated output current shall be decreased by 1% for every rise of 100m | ||
Vibration | 3.5mm, 2~9Hz; 10 m/s 2,9~200Hz; 15 m/s, 200~500Hz | ||
Storage temperature | -40~+70ºC | ||
Motor Wiring
It is forbidden to short circuit the Hydraulic Servo Drive Controller output terminals or short circuit to ground, otherwise the internal components of the variable frequency inverter will be damaged.
Do not short circuit the output cable to the universal variable frequency drive enclosure, otherwise electric shock may happen.
It is forbidden to connect the output terminal of the inverter to the capacitor or LC/RC noise filter with phase lead, otherwise, the internal components of the inverter may be damaged.
When contactor is installed between the inverter and motor, it is forbidden to switch on/off the contactor when the V&T AC Frequency Drive is running; otherwise, large current will flow into the industrial inverter, triggering the inverter protection action.
Length of cable between the 3 Phase Frequency Converter and motor. If the cable between the frequency inverter and the motor is too long, the high−order harmonic leakage current of the output end will cause adverse impact on the Single Phase To 3 Phase Inverter Converter and the peripheral devices. Output AC reactor should be installed if the motor cable is longer than 100m, Refer to the following table for the switching frequency setting.
Installation dimension
![]() | ![]() |
![]() | ![]() |
VY−IS−4T11−I0(20180402)−06−24 and above power class
VY−IS Product outline, mounting dimension, and weight
Voltage class | Driver model | Outline and mounting dimension (mm) | Approximate weight (kg) | |||||||
W | H | D | W1 | H1 | D1 | T1 | Hole d | |||
400V | VY−IS−4T0.75−I0(20180402)−24 | 118 | 190 | 155 | 105 | 173 | 40.8 | 3 | 5.5 | 1.5 |
VY−IS−4T1.5−I0(20180402)−24 | 118 | 190 | 175 | 105 | 173 | 60.5 | 4 | 5.5 | 2.6 | |
VY−IS−4T2.2−I0(20180402)−24 | ||||||||||
VY−IS−4T3.7−I0(20180402)−24 | ||||||||||
VY−IS−4T5.5−I0(20180402)−24 | 155 | 249 | 185 | 136 | 232 | 69 | 8 | 5.5 | 3 | |
VY−IS−4T7.5−I0(20180402)−24 | ||||||||||
VY−IS−4T11−I0(20180402)−24 | 210 | 337 | 200 | 150 | 324 | 107.5 | 2.5 | 7 | 8.5 | |
VY−IS−4T15−I0(20180402)−24 | ||||||||||
VY−IS−4T18.5A−I0(20180402)−06−24 | 285 | 440 | 220 | 200 | 425 | 107.5 | 2.5 | 7 | 17 | |
VY−IS−4T22A−I0(20180402)−06−24 | ||||||||||
VY−IS−4T30A−I0(20180402)−06−24 | ||||||||||
VY−IS−4T37A−I0(20180402)−06−24 | 315 | 575 | 227 | 220 | 553 | 123.5 | 2.5 | 10 | 25 | |
VY−IS−4T45A−I0(20180402)−06−24 | ||||||||||
VY−IS−4T55A−I0(20180402)−06−24 | 400 | 615 | 265 | 270 | 590 | 123.5 | 3.0 | 10 | 35 | |
VY−IS−4T75A−I0(20180402)−06−24 | ||||||||||
VY−IS−4T90−I0(20180402)−24 | 465 | 745 | 325 | 343 | 715 | 156 | 3.0 | 12 | 55 | |
VY−IS−4T110−I0(20180402)−24 | ||||||||||
VY−IS−4T132−I0(20180402)−24 | 540 | 890 | 385 | 370 | 855 | 205.5 | 4.0 | 14 | 85 | |
VY−IS−4T160−I0(20180402)−24 | ||||||||||
VY−IS−4T185−I0(20180402)−24 | ||||||||||
VY−IS−4T200−I0(20180402)−24 | ||||||||||
VY−IS−4T220−I0(20180402)−24 | 700 | 1010 | 385 | 520 | 977 | 210 | 4.0 | 14 | 125 | |
VY−IS−4T250−I0(20180402)−24 | ||||||||||
VY−IS−4T280−I0(20180402)−24 | ||||||||||
VY−IS−4T315−I0(20180402)−24 | 810 | 1358 | 425 | 520 | 1300 | 210 | 4.0 | 14 | 215 | |
VY−IS−4T355−I0(20180402)−24 | ||||||||||
VY−IS−4T400−I0(20180402)−24 | 810 | 1358 | 425 | 520 | 1300 | 210 | 4.0 | 14 | 215 | |
VY−IS−4T450−I0(20180402)−24 | ||||||||||
VY−IS−4T500−I0(20180402)−24 | ||||||||||
Applications
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Representative Industry
As an advanced China Hydraulic Drive System Manufacturers,The use of V&T frequency drive (VFDs): a VFD is used to regulate the speed and torque of the Motor according to the variation of the load in order to improve the Motor energy efficiency. The technology of AC-VFD-AC drives power overcomes the small range and poor speed adjustment performance. Shenzhen V&T Technologies Co.,Ltd. AC servo drives is suitable for Air Compressor Speed Drive, Injection moulding machine drive system, Die Casting Machine AC Drive, Energy-saving industry etc

Download
undefined
VY-IS Series High Performance Servo Drive
Product Model:
Categories:
Keywords:
Download File:
overseas@v-t.net.cn
Online Message
Ready to grow your business? Your next great business opportunity starts with an inquiry.