Product introduction

Product Overview

ItemDescription
Product NameV6-T Tension Control Inverter
Model NumberV6-T-4Txxx
Power Range0.75kW-500kW
Rated Input Voltage3 Phase 380V/480V
Rated Output Voltage3 phase 0 to rated input voltage
Input Frequency50Hz/60Hz
Applicable MotorAsynchronous Motor
Control ModeTension Control, V/F Vector Control, Sensor-less Vector Control, Sensor Vector Control, Vector Torque Control
CommunicationModbus 485 RTU
IP CodeIP20
Overload Capacity150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)

 

Feature

■ Tension Control VFD Drive : Simple and reliable, cost-saving, easy to maintain on system, optional industry experience value, built-in control scheme, and wide range of applications

■ Diversified application of parameters, unified parameter setting, and intelligent parameter setting

■ Various tension schemes, anti-speed function, compensation on tension dynamic , built-in automatic roll change, tension taper function, roll diameter self-learning, PID adaptive function, encoder scheme, excellent vector performance

■ Remote commissioning assistant and the system runs stably within two steps

 

Model Explanation


 

Product Catalog

V6-T-4TXXX ;

Power (kW)0.751.52.23.75.57.5111518.5223037455575
Motorpower (kW)0.751.52.23.75.57.5111518.5223037455575
OutputVoltage (V)Three-phase 0 to rated input voltage
Rated current (A)2.53.85.59131724303945607591112150
Overloadcapacity150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lagfeature)
InputRatedvoltage/frequencyThree-phase 380V/480V; 50Hz/60Hz
Allowable voltagerange323V ~ 528V; Voltage imbalance ≤3%; allowable frequency fluctuation: ±5%
Rated current (A)2.84.26.1101519263343506683100123165
Braking unitBuilt-in as standardBuilt-in as option
Protection classIP 20
Cooling modeNatural−coolingForced air cooling
Power (kW)90110132160185200220250280315355400450500
 
Motorpower (kW)90110132160185200220250280315355400450500
 
OutputVoltage (V)Three-phase 0 to rated input voltage
Rated current (A)176210253304350380426470520600650690775860
 
Overloadcapacity150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lagfeature)
InputRatedvoltage/frequencyThree-phase 380V/480V; 50Hz/60Hz
Allowable voltagerange323V ~ 528V; Voltage imbalance ≤3%; allowable frequency fluctuation: ±5%
Rated current (A)160*196*232*282*326*352*385*437*491*580*624*670*755*840*
 
Braking unitExternal braking unit needed
Protection classIP 20
Cooling modeForced air cooling

 

Technical Parameters

control methodHigh performance vector control tension control
Power range0.75kW~500 kW
Input voltage frequency3AC 380V~480V;50Hz/60Hz
Input voltage frequency3AC 0 ~ rated input voltage
Output frequency0.0~300.0Hz
Digital input and output

Standard multi-function input terminal, expandable

Standard open collector output, expandable

Analog input and output

Input: AI1 0~20 mA, input impedance 500Ω, maximum input current 30mA;

0 to 10V, input impedance 20kΩ,

Maximum input voltage 15V, resolution is 12 bits (0.025%)

Select 0 to 20 mA or 0 to 10V analog input by jumper;

AI2 Same as above

AI3 −10V~10V, input impedance 20kΩ maximum input voltage ±15V, resolution 12 bits (0.025%)

Output: AO1 0~20 mA, output allowable impedance 200~500Ω

0 to 10V, output allowable impedance ≥10kΩ, resolution is 10 bits (0.1%)

Short-circuit protection function, select 0~20 mA or 0~10V analog output by jumper;

AO2 Same as above

Pulse input and output

Pulse input: 0.1Hz ~ 50kHz; voltage range: 24V ± 20%

Pulse output: 0 ~ 50kHz; voltage range: 24V ± 20%

ProtocolDual 485 communication interface supports Modbus protocol (RTU), standard operation panel can realize remote control, up to 500 meters
Brake unit

15kW and lower power grades are built-in;

18.5kW ~ 75kW power grades are built-in as optional;

90kW and higher power grades need to be external;

External interfaceDC24V power supply, maximum output current 100 mA
DC reactor90kW and higher power grades models are standard with external DC reactor
Installation methodWall mounting
Protection levelIP 20

 

Model table

Voltage

Model

Single/three phase 200 V constant torque / heavy duty application

Motor (kW)

Rated output current (A)

Rated input current (A)

400V

V5/V6−T−4T0.750.752.52.81.53.33.6
V5/V6−T−4T1.51.53.84.22.25.05.5
V5/V6−T−4T2.22.25.56.13.77.58.3
V5/V6−T−4T3.73.79105.51112
V5/V6−T−4T5.55.513157.51719
V5/V6−T−4T7.57.51719112225
V5/V6−T−4T11112426153033
V5/V6−T−4T1515303318.53740
V5/V6−T−4T18.5A*18.53943224450
V5/V6−T−4T22A224553305662
V5/V6−T−4T30A306066377280
V5/V6−T−4T37A3775834591100
V5/V6−T−4T45A459110055110121
V5/V6−T−4T55A5511212375142156
V5/V6−T−4T75A7515016590176194
V5/V6−T−4T9090176160110210196
V5/V6−T−4T110110210196132253232
V5/V6−T−4T132132253232160304282
V5/V6−T−4T160160304282185350326
V5/V6−T−4T185185350326200380352
V5/V6−T−4T200200380352220426385
V5/V6−T−4T220220426385250470437
V5/V6−T−4T250250470437280520491
V5/V6−T−4T280280520491315600580
V5/V6−T−4T315315600580355650624
V5/V6−T−4T355355650624400690670
V5/V6−T−4T400400690670450775755
V5/V6−T−4T450450775755500860840
V5/V6−T−4T500500860840450950920

In this table, “A” indicates the structure version, and the default is the original version, which is A, B······.
 

Installation Dimensions


 

 
V5/V6−T−4T7.5 and below power class 

 

 

V5/V6−T−4T11 and above power class

Voltage

Model

Appearance and installation dimensions (mm)

weight (kg)
WHDW1H1D1T1Hole d

400V

V5/V6−T−4T0.7511819015510517340.835.51.5
V5/V6−T−4T1.511819017510517360.545.52.6
V5/V6−T−4T2.2
V5/V6−T−4T3.7
V5/V6−T−4T5.51552491851362326985.5; ;3
V5/V6−T−4T7.5
V5/V6−T−4T11210337200150324107.52.578.5
V5/V6−T−4T15
V5/V6−T−4T18.5A*285440220200425107.52.5717
V5/V6−T−4T22A
V5/V6−T−4T30A
V5/V6−T−4T37A315575227220553123.52.51025
V5/V6−T−4T45A
V5/V6−T−4T55A400615265270590123.53.01035
V5/V6−T−4T75A
V5/V6−T−4T904657453253437151563.01255
V5/V6−T−4T110
V5/V6−T−4T132540890385370855205.54.01485
V5/V6−T−4T160
V5/V6−T−4T185
V5/V6−T−4T200
V5/V6−T−4T22070010103855209772104.014125
V5/V6−T−4T250
V5/V6−T−4T280
V5/V6−T−4T315810135842552013002104.014215
V5/V6−T−4T355
V5/V6−T−4T400810135842552013002104.014215
V5/V6−T−4T450
V5/V6−T−4T500

 

Optional Expansion Card

CategoryNameModelFunction ExplanationRefer
Operation panelOperation panel (shuttle type)V6−DP01Standard models of 7.5kW and belowP2−**
Operation panel (button type)V6−DP0211kW and above models are standardP2−**
Text displayEX−MT01Man-machine interface - text displayP2−**
touch screenEX−MT02Human-machine interface - touch screenP2−**
Fake panelV6−DP03Customer optionP2−**
PalletV6−DP05Operation panel mounting accessoriesP2−**
Expansion CardPower monitor cardEX−PA01Three-phase input power supply phase loss / instantaneous power failure monitoringP2−**
Phase-sequence detection cardEX−PA02Three-phase input power phase detectionP2−**
Speed tracking cardEX−PA03Speed trackingP2−**
External power rectification cardEX−RF01Control power is provided by external power supplyP2−**
Programmable CAN bus extension cardEX−CA05;P2−**
Profibus DP communication cardEX−CA06;P2−**
Keyboard extension cord2 m keyboard extension cordCB1−200;P2−**
3 ;m keyboard extension cordCB1−300;P2−**
BaseInverter base;Optional for 90kW and above power models;
PG card (V6−T for option)PG feedback card (12V)EX−PG01A/B/Z open collector/differential/push-pullP2−**
PG feedback card (5V)EX−PG02A/B/Z open collector/differential/push-pullP2−**
PG feedback with frequency dividing output (12V)EX−PG0312V−PG feedback cassette with crossover outputP2−**
PG feedback with frequency dividing output (5V)EX−PG045V−PG feedback cassette with crossover outputP2−**
PG Feedback card for UVW code diskEX−PG06Feedback card for UVW code diskP2−**
PG Feedback card/rotary transformerEX−PG07Feedback card for resolverP2−**

 

Applications


 

 

 

 

 

 

 

 

 

Tension Frequency Drive Representative Industry

Speed control application that there is a roll diameter calculation and tension with pendulum but no encoder. such as warping machine Inverter, sizing machine, dyeing machine, non-woven slitting machine, winding machine, laminating machine, coating Machine, laminating machine, laminating machine, bag cutting machine, single frequency conversion, double frequency conversion, straight wire drawing machine, cable machine, paper machine, slitting machine, surface reeling machine, rewinding machine, gravure printing machine, Flexographic printing machines, dyeing machines, dyeing machines, metal processing cold-rolling machines, hot-rolling machines, layer winding machines, winding machines, unwinding frames, leather winders, extruders, etc. In addition,the Shenzhen V&T Technologies Co.,Ltd. V6−T can be used as an replacement torque motor with torque control and constant tension control and it can also be used as replacing magnetic powder clutch.

Download

undefined

undefined

V6-T Tension Control Inverter

Product Model:

V6−T is a special inverter with high-performance torque control and sensor vector control on Tension Control. It devotes to controlling speed with an encoder, roll diameter calculation and tension pendulum and also or not. With the requirements met on rewinding and unwinding machine, it not only achieves requirements of cost saving, improvement on product quality and production efficiency,but also easy maintenance and easy commissioning.

Keywords:

Download File:


E-mail

Online Message

Ready to grow your business? Your next great business opportunity starts with an inquiry.


Security verification
Send Inquiry Now