Product introduction

Product Overview

ItemDescription
Product NameFrequency Inverter/ AC Drive
Model NumberV5/V6-GH-4TxxG,V5/V6-GA-4TxxG
Power Range0.75kW-500kW
Rated Input Voltage3 phase 380V/480V
Rated Output Voltage3 phase 0 to rated input voltage
Input Frequency50Hz/60Hz
Applicable MotorAsynchronous Motor
Control ModeV/F Control, Vector Control, Sensor-less Vector Control, Sensor Vector Control, Vector Torque Control
CommunicationModbus 485 RTU
IP ClassStandard IP20
Overload Capacity150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)

 

Feature

■ Perfect combination of PLC and high performance vector inverter on professional crane function

Hoist Crane Inverter has strong startup torque under low frequency

■ Reliable brake control to eliminate glide-hook

■ Smooth and reliable lifting speed

■ Greater overload capacity

■ Better power optimization

■ Position processing and intelligent deceleration

■ Standard international bus communication and optimized communication format

■ Safe and sound keyboard operation

■ Comprehensive monitoring and protection with fault

 

Model Explanation

 

Product Catalogue

V6−GH−4T□□□G□  and V5−GH−4T□□□G□ ; Three-phase 400V Constant torque/heavy-duty application

Power(kW)0.40.751.52.23.75.57.5111518.52230374555
Motor power(kW)0.40.751.52.23.75.57.5111518.52230374555
OutputVoltage (V)Three-phase 0 to rated input voltage
Rated current (A)2.53.85.59131724303945607591112150
Overload capacity150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)
InputRated Voltage /frequencyThree-phase 380V/480V; 50Hz/60Hz
Allowable voltage range323V ~ 528V; Voltage unbalance ≤3%; allowable frequency fluctuation: ±5%
Rated current (A)2.84.26.1101519263343506683100123165
Braking unitBuilt-in as standard
Protection classIP 20
Cooling modeNatural coolingForced air convection cooling
Power (kW)7590110132160185200220250280315355400450
 
Motor power (kW)7590110132160185200220250280315355400450
 

 
OutputVoltage (V)Three-phase 0 to rated input voltage
Rated current (A)176210253304350380426470520600650690775860
 
Overload capacity150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)
InputRated Voltage/frequencyThree-phase 380V/480V; 50Hz/60Hz
Allowable voltage range323V ~ 528V; Voltage unbalance≤3%; allowable frequency fluctuation: ±5%
Rated current (A)160*196*232*282*326*352*385*437*491*580*624*670*755*840*
 
Braking unitExternal braking unit needed
Protection classIP 20
Cooling modeForced air convection cooling

* V6-GH-4T75G and V5-GH-4T75G above products are equipped with external DC reactor as standard.

*1 0.4~22kW structure version is A, 30~37kW structure version A means the main circuit is DC contactor, B is relay, 45kW and above need not be noted.

*2 0.4 to 55kW standard built-in brake unit, 15kW to 55kW If the brake unit is not required, the model must be equipped with −56, Products with 75kW and above must have an external brake unit.

 

V6−GA−4T□□□G□ and V5−GA−4T□□□G□ ; Three-phase 400V Constant torque/heavy-duty application

Power (kW)

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

75

Motor power (kW)

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

75

Output

Voltage (V)

Three-phase 0 to rated input voltage

Rated current (A)

2.5

3.8

5.5

9

13

17

24

30

39

45

60

75

91

112

150

Overload capacity

150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)

Input

Rated Voltage

/frequency

Three-phase 380V/480V; 50Hz/60Hz

Allowable voltage range

323V ~ 528V; Voltage unbalance ≤3%; allowable frequency fluctuation: ±5%

Rated current (A)

2.8

4.2

6.1

10

15

19

26

33

43

50

66

83

100

123

165

Braking unit

Built-in as standard

Protection class

IP 20

Cooling mode

Natural cooling

Forced air convection cooling

Power (kW)

90

110

132

160

185

200

220

250

280

315

355

400

450

500

 

Motor power (kW)

90

110

132

160

185

200

220

250

280

315

355

400

450

500

 

Output

Voltage (V)

Three-phase 0 to rated input voltage

Rated current (A)

176

210

253

304

350

380

426

470

520

600

650

690

775

860

 

Overload capacity

150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)

Input

Rated Voltage /frequency

Three-phase 380V/480V; 50Hz/60Hz

Allowable voltage range

323V ~ 528V; Voltage unbalance ≤3%; allowable frequency fluctuation: ±5%

Rated current (A)

160*

196*

232*

282*

326*

352*

385*

437*

491*

580*

624*

670*

755*

840*

 

Braking unit

External braking unit needed

Protection class

IP 20

Cooling mode

Forced air convection cooling

* V6−GA−4T90G and V5−GA−4T90G above products are equipped with external DC reactor as standard.

*1 0.7~30kW structure version is A, 37~45kW structure version A means the main circuit is DC contactor, B is relay, 55kW and above need not be noted.

*2 0.7 to 75kW standard built-in brake unit, 18.5kW to 75kW If the brake unit is not required, the model must be equipped with −56, Products with 90kW and above must have an external brake unit.

 

Terminal Wiring diagram


 

Installation Dimension


 

 

V6/V5−GH−4T5.5G,V6/V5−GA−4T7.5G and below power class


 

 

V6−GH−4T7.5G,V6−GA−4T11G and above power class 

Product Appearance, Installation Dimensions, Approximate Weight

voltage

Inverter item

product outline, mounting dimension(mm)

weight(kg)

W

H

D

W1

H1

D1

T1

Install hole d

400V

V6/V5−GH−4T0.4G

V6/V5−GA−4T0.75G

118

190

155

105

173

40.8

3

5.5

1.5

V6/V5−GH−4T0.75G

V6/V5−GA−4T1.5G

118

190

175

105

173

60.5

4

5.5

2.6

V6/V5−GH−4T1.5G

V6/V5−GA−4T2.2G

V6/V5−GH−4T2.2 G

V6/V5−GA−4T3.7G

V6/V5−GH−4T3.7G

V6/V5−GA−4T5.5G

155

249

185

136

232

69

8

5.5

; ;3

V6/V5−GH−4T5.5G

V6/V5−GA−4T7.5G

V6/V5−GH−4T7.5G

V6/V5−GA−4T11G

210

337

200

150

324

107.5

2.5

7

8.5

V6/V5−GH−4T11G

V6/V5−GA−4T15G

400V

V6/V5−GH−4T15G

V6/V5−GA−4T18.5G

285

440

220

200

425

107.5

2.5

7

17

V6/V5−GH−4T18.5G

V6/V5−GA−4T22G

V6/V5−GH−4T22G

V6/V5−GA−4T30G

V6/V5−GH−4T30G

V6/V5−GA−4T37G

315

575

227

220

553

123.5

2.5

10

25

V6/V5−GH−4T37G

V6/V5−GA−4T45G

V6/V5−GH−4T45G

V6/V5−GA−4T55G

400

615

265

270

590

123.5

3.0

10

35

V6/V5−GH−4T55G

V6/V5−GA−4T75G

V6/V5−GH−4T75G

V6/V5−GA−4T90G

465

745

325

343

715

156

3.0

12

55

V6/V5−GH−4T90G

V6/V5−GA−4T110G

V6/V5−GH−4T110G

V6/V5−GA−4T132G

540

890

385

370

855

205.5

4.0

14

85

V6/V5−GH−4T132G

V6/V5−GA−4T160G

V6/V5−GH−4T160G

V6/V5−GA−4T185G

V6/V5−GH−4T185G

V6/V5−GA−4T200G

V6/V5−GH−4T200G

V6/V5−GA−4T220G

700

1010

385

520

977

210

4.0

14

125

V6/V5−GH−4T220G

V6/V5−GA−4T250G

V6/V5−GH−4T250G

V6/V5−GA−4T280G

V6/V5−GH−4T280G

V6/V5−GA−4T315G

810

1358

425

520

1300

210

4.0

14

215

V6/V5−GH−4T315G

V6/V5−GA−4T355G

V6/V5−GH−4T355G

V6/V5−GA−4T400G

V6/V5−GH−4T400G

V6/V5−GA−4T450G

V6/V5−GH−4T450G

V6/V5−GA−4T500G

Note: the detailed definition of W, H, D, W1, H1, D1, T1 and installation hole D should refer to the standard specification.

 

Applications


 

 

 

 

 

 

 

 

 

 

Representative Industry and Applicable Machine

The 3 phase vector control Inverter of Shenzhen V&T Technologies Co.,Ltd. are widely used in Port, Ship, Marine Engineering, Mining, Construction, Metallurgy, Factories and other industries.

Port Wheel Crane, Gantry Crane, Tower Crane, Hoist, Electric Hoist, Crane, Mine Hoist, Winch, Grab Control and other machines.

Download

undefined

undefined

Inverter for Hoist/Crane

Product Model:

V6-G and V5-G series are special inverter for high performance hoist. The product adopts the torque vector control technology with the current international advanced technology. This product has excellent torque control, reliable brake control on time and sequence, speed monitoring, torque monitoring, power optimization, position processing, intelligent deceleration and other functions.

Keywords:

Download File:


E-mail

Online Message

Ready to grow your business? Your next great business opportunity starts with an inquiry.


Security verification
Send Inquiry Now