Product introduction
Profibus-DP Communication Card Installation
Power supply connection
Power supply method 1: Insert EX-CA06 to the frequency converter control board extension interface(CN3).
Power supply method 2: The “+24V” terminal of EX-CA06 should be connected to "+24V" terminal of the frequency converter control board; The “COM” terminal of EX-CA06 should be connected to “COM” terminal of the frequency converter control board.
Communication signal connection
The “485+” terminal of EX-CA06 should be connected to “485+” terminal of the frequency converter control board; The “485-” terminal of EX-CA06 should be connected to “485-” terminal of frequency converter control board; The “GND” terminal of EX-CA06 should be connected to “GND” terminal of the frequency converter control board.
Note: Twisted pair cable should be used.
The connection method is serial connection. The DB9 connector at both ends are only connected to A1, B1, and the terminal resistor is on. The terminal resistor at intermediate node of the network is off. A1, B1, A2, B2 are all wired.

Shenzhen V&T Technologies Co.,Ltd. electric drive products voltage class mainly contains 200V, 400V, 690V, 1140V, and the power class varies from 0.4kW to 3000kW, which could meet various application demands from high, medium and low level market. So far V&T products have been exported to over 60 countries like Korea, Germany, England, Russia, UAE, Pakistan, Thailand, India, Australia, South Africa, Mexico etc.

Download
undefined
EX-CA06 Profibus-DP Communication Adapter Card
Product Model:
Categories:
Keywords:
Download File:
overseas@v-t.net.cn
Online Message
Ready to grow your business? Your next great business opportunity starts with an inquiry.