Product introduction

Product Overview

ItemDescription
Product NameFrequency Inverter/ AC Drive
Model NumberV9-H-4TxxG/xxL
Power Range0.75kW-630kW
Rated Input Voltage3 phase 380V/480V
Rated Output Voltage3 phase 0 to rated input voltage
Input Frequency50Hz/60Hz
Applicable MotorAsynchronous Motor, Synchronous Motor
Control ModeV/F Control, Vector Control, Sensorless Vector Control, Sensor Vector Control, Vector Torque Control
CommunicationModbus 485 RTU, CANOpen, Profibus-DP, Profinet
IP ClassStandard IP20
Overload Capacity150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)

 

Feature

■ Fast and accurate motor parameter self-learning, suitable for a variety of motors: synchronous/asynchronous/reluctance/high-speed/torque motor, VF vector encoder closed loop integrated

3 Phase Motor Inverter Asynchronous and non-inductive VF control, 200% torque output at 0.25Hz in electric state, 200% torque output at 1Hz in power generation state

■ Good voltage and current control, high speed, high frequency, deep field weakening, wave-by-wave current limiting, multiple protections

■ Modular compact structure design, high power density

■ Support multiple encoders and multiple high-speed communication protocols

■ Integrated drive and control, expandable PLC and motion control card

■ Multiple language keyboard, friendly interface, reliable and easy to use

 

Model Explanation

 

Product Catalogue

V9−H−4T□□□G Three-phase 400V constant torque / heavy duty Application

Power(kW)0.751.52.23.75.57.5111518.522303745557590110
Motor power (kW)0.751.52.23.75.57.5111518.522303745557590110
OutputVoltage (V)3-phase 0 -rated input voltage
Ratedcurrent (A)2.53.85.59131724303945607591112150176210
Overload capability150% 1 min,180% 10 s, 200% 0.5 s,10 min interval (Inverse-time characteristic)
InputRatedvoltage / frequency3-phase 380V-480V; 50Hz/60Hz
Allowable voltage323V-528V; degree of voltage unbalance:≤3%; allowable frequency fluctuations:±5%
Ratedcurrent (A)2.84.26.1101519263343506683100123165194231
Brake unitStandard built-inBuilt-in brake unit is optional
Protection levelIP 20
Cooling methodSelf−coolingForced cooling
Power(kW)132160185200220250280315355400450500560630
Motor power (kW)132160185200220250280315355400450500560630
OutputVoltage (V)3-phase 0 -rated input voltage
Rated current (A)2533043503804264705206006506907758609501100
Overloadcapability
150% 1min,180% 10s, 200% 0.5s,10min interval (Inverse-time characteristic)
InputRatedvoltage / frequency3-phase 380V-480V; 50Hz/60Hz
Allowablevoltage323V-528V; degree of voltage unbalance:≤3%; allowable frequency fluctuations:±5%
Ratedcurrent (A)2322823263523854374915806246707558409201050
Brake unitExternal braking unit needed
Protection levelIP20
Cooling methodForced cooling

Note: 

0.75kW~15kW:No built-in DC reactor ;

18.5kW~110kW:Optional DC reactor ;

132kW~160kW:Standard built-in DC reactor ;

185kW~500kW:Standard external DC reactor;

560kW~630kW:Standard built-in AC input reactor;

Higher power level product can be customized

220V, 690V, 1140Vand other voltage level inverters can be customized.

 

V9−H−4T□□□LThree−phase 400V Variable torque/light−duty Application

Power(kW)1.52.23.75.57.5111518.522303745557590110132
Motor power (kW)1.52.23.75.57.5111518.522303745557590110132
OutputVoltage(V)3-phase 0 -rated input voltage
Rated current (A)3.357.5111722293545577091110144180216242
Overload capability120% 1 min,160% 0.5 s,10 min interval (Inverse-time characteristic)
InputRated voltage /frequency3-phase 380V-480V; 50Hz/60Hz
Allowablevoltage
323V-528V; degree of voltage unbalance:≤3%; allowable frequency fluctuations:±5%
Rated current (A)3.65.58.31219253239506177100121158198238266
Brake unitStandard built-inBuilt-in brake unit is optional
Protection levelIP20
Cooling methodSelf−coolingForced cooling
Power(kW)160185200220250280315355400450500560630710
Motor power (kW)160185200220250280315355400450500560630710
OutputVoltage (V)3-phase 0 -rated input voltage
Rated current(A)
325365405440495547610695770866950110012001300
Overload capability120% 1 min,160% 0.5 s,10 min interval (Inverse-time characteristic)
InputRated voltage /frequency3-phase 380V-480V; 50Hz/60Hz
Allowable voltage
323V-528V; degree of voltage unbalance:≤3%; allowable frequency fluctuations:±5%
Ratedcurrent (A)282326352385437491580670755840920105011501250
Brake unitExternal braking unit needed
Protection levelIP 20
Cooling method
Forced cooling

Note:  

1.5kW - 18.5kW: No built-in DC reactor ;

 22kW~132kW: Optional DC reactor ;

 160kW~185kW: Standard built-in DC reactor ;

 200kW~560kW: Standard external DC reactor ;

 630kW~710kW: Standard built-in AC input reactor;

 Higher power level product can be customized ;

 220V, 690V, 1140V and other voltage level inverters can be customized.

 

Technical Specification

Control characteristics

Control mode

Sensor-less control

Sensor control

Applicable motor type

Synchronous motor

Asynchronous motor

Synchronous motor

Asynchronous motor

Starting torque

● Asynchronous motor: 200% of rated torque at 0.25Hz

● Synchronous motor: 150% of rated torque at 1.5% of rated speed

200% of rated torque at 0 speed

Speed regulation range

1:200

1:5000

Steady speed precision

± 0.5%

± 0.02%

Maximum speed

VF control: 600Hz

Vector control: 600 Hz ;

Note: Higher frequency products can be customized

600Hz

Note: Higher frequency products can be customized

Torque control

Y

Y

Torque control precision

±5%

±3%

Torque response time

<20 ms

<10 ms

Positioning control

N

Y

Positioning ;precision

N

±1 ;pulse

Product function

Key function

Torque limit, speed control, positioning control, motor auto tune, deep flux-weakening control, current limit control, over-voltage control, under-voltage control, motor speed tracing function, droop control, oscillation suppression, random carrier frequency, inertia auto-tune, etc.

Speed reference source

Modbus communication, Keypad, external digital input, analog ;AI1/AI2/AI3, high speed pulse input, simple PLC, PID, CAN, PROFIBUS DP, PROFINET, etc.

Dynamic brake

Brake unit action voltage: 650 ~ 750V.

The brake unit can be built-in for 110kW and below equipment

0.75~15 kW: brake unit is built- in as standard.

● 18.5~110 kW: brake unit is built- in as optional.

Communication

Built-in Modbus-RTU communication, the maximum distance up to 500 meters.

Keypad

LED Keypad and LCD Keypad are optional

the Keypad can be used as remote-control box via straight-through wired cable. 

Common DC bus

Support common DC bus directly

Independent air duct

All series product adopts independent duct design

Protection function

Power supply under-voltage, over-current protection, over-voltage protection, auto-tune fault, module protection, heat-sink over-temperature protection, drive overload protection, motor overload protection, peripheral protection, current abnormal detection, output short-circuit to ground protection, EEPROM abnormal detection, temperature sampling disconnection, encoder disconnection, analog input abnormal detection, motor over-temperature, communication fault, hardware overload protection, etc.

Efficiency

At rating condition:

● 0.75kW to 7.5kW: ≥ 93%

● 11kW to 45kW: ≥ 95%

● 55kW and higher power class: ≥ 98%

Environment

Operating site

● Install vertically in a well-ventilated electrical cabinet. Horizontal or other installation methods are not allowed.

● The cooling medium is air.

● Installed in an environment free from direct sunlight, dust, corrosive gases, flammable gases, no oil mist, no steam, no dripping.

Ambient temperature

● −10~+40℃

● Derating use when the temperature between 40 to 50℃, the rated output current is reduced by 1% for every 1 °C increasing.

Humidity

5~95%, no condensation is allowed.

Altitude

● 0~2000 meters

● Derating use when the altitude over 1000 meters, the rated output current is reduced by 1% for every 100-meter rising.

Vibration

● 3.5 m/s2, 2~9Hz

● 10 m/s2, 9~200Hz

● 15 m/s2, 200~500Hz

Storage temperature

−40~+70℃.

 

Motor Wiring

Short circuit or grounding of the variable frequency controller output terminals is prohibited. Otherwise, it will cause damage to the internal VFD Inverter Components.

Avoid output cables (U/V/W) short circuit or short circuit to enclosure, otherwise there is a risk of electric shock.

It is strictly forbidden to connect a capacitor or phase lead LC/RC noise filter to the output of the AC Converter Drive, otherwise the drive will be damaged.

When a contactor is installed between the High quality VFD and the motor, the switching action of the output contactor cannot be performed during the operation of the drive, otherwise a large current will flow into the drive to and the drive will report fault information.

Cable length between drive and motor: When the cable between the RS485 Modbus Frequency Drive and the motor is too long, the high-order harmonic leakage current at the output will adversely affect the drive and peripheral devices. It is recommended to install a output AC reactor when the motor cable exceeds 100 meters, and contact the manufacturer to inquire whether the carrier frequency needs to be modified.

  

 

Installation dimension


 

 

V9−H−4T7.5G/11L and below power class


 

 

 

V9−H−4T11G/15L and above power class

Voltage

Model

Outline and mounting dimension (mm)

Weight (kg)

W

H

D

W1

H1

T1

Mounting hole diameter d

400V

V9−H−4T0.75G/1.5L

118

190

155

105

173

3

5.5

1.5

V9−H−4T1.5G/2.2L

118

190

175

105

173

4

5.5

2.6

V9−H−4T2.2G/3.7L

V9−H−4T3.7G/5.5L

V9−H−4T5.5G/7.5L

155

249

185

136

232

8

5.5

3

V9−H−4T7.5G/11L

V9−H−4T11G/15L

198

299

190

160

283

1.2

6

8

V9−H−4T15G/18.5L

V9−H−4T18.5G/22L

223

348

208

195

335

1.5

6

10

V9−H−4T22G/30L

V9−H−4T30G/37L

264

430

235

230

418

1.5

7

18

V9−H−4T37G/45L

V9−H−4T45G/55L

305

545

270

245

523

1.5

10

35

V9−H−4T55G/75L

V9−H−4T75G/90L

338

580

310

270

560

1.5

10

52

V9−H−4T90G/110L

V9−H−4T110G/132L

V9−H−4T132G/160L

400

917

323

320

890

3.0

12

75

V9−H−4T160G/185L

V9−H−4T185G/200L

540

890

385

370

855

4.0

14

85

V9−H−4T200G/220L

V9−H−4T220G/250L

540

890

416

370

855

4.0

14

85

V9−H−4T250G/280L

700

1010

385

520

977

4.0

14

125

V9−H−4T280G/315L

V9−H−4T315G/355L

700

1010

418.5

520

977

4.0

14

125

V9−H−4T355G/400L

810

1358

425

520

1300

4.0

14

215

V9−H−4T400G/450L

810

1358

425

520

1300

4.0

14

215

V9−H−4T450G/500L

V9−H−4T500G/560L

Applications


 

 

 

 

 

 

 

 

 

VFD Electrical Electronic Engineering Representative Industry

AC drives are used to bring about process and quality improvements in industrial and commercial applications' acceleration, flow, monitoring, pressure, speed, temperature, tension, and torque. Whenever a load has either a variable torque or a variable speed, a VFD should be considered to control torque and speed. V9 series universal speed AC drive of Shenzhen V&T Technologies Co.,Ltd. is suitable for V&T Pump Drives, Printing Packaging, Petrochemical, Textile, Cable Machinery, Food Packaging, Electric Vehicles, Plastic Machinery, Metal Products Equipment, Centrifuges and High-end applications requiring closed-loop vector or torque control.

Download

undefined

undefined

250kW-500kW V9 Series High Performance Universal Speed AC Drive

Product Model:

As the VFD manufacturer in china, V&T has rich experience in electric drive fields. V&T V9−H Series General Purpose Inverter is a high-performance vector control and torque controlled frequency drive. Vector control technology and torque control technology are employed. It can better meet the needs of various transmission applications.Voltage range covers 200V, 400V, 690V, and 1140V. The product power range covers 0.4kW to 3MW.

Keywords:

Download File:


E-mail

Online Message

Ready to grow your business? Your next great business opportunity starts with an inquiry.


Security verification
Send Inquiry Now